Rack Request Form

heat-craft

+ RACK STANDARD FEATURES - CLICK TO VIEW

Painted welded structural steel frame Oil System:

  • Coalescent oil seperator

Copeland Discus Compressors: (With following mounted)

  • Sealed oil filter
  • Suction and discharge service valves
  • Oil pressure reducing valve
  • Oil regulator
  • Discharge line check valve
  • Oil Regulator adapter. ( 4D & 6D compressors)
  • Discharge vibration eliminator Electrical:
  • Crankcase heater
  • ETL-508A listed control panel
  • Encapsulated fixed high pressure control
  • Definite purpose contactors
  • Head cooling fan (low temp. only)
  • Compressor circuit breakers
  • Demand cooling for R22 low temp. applications
  • Phase monitor with alarm light
  • Discharge muffler plate
  • Fused control circuit transformer
  • Rubber vibration mounts
  • Control circuit, circuit breaker
  • Independent switches and lights per defrost circuits
  • Independent switches and lights per compressor circuits

Liquid Assembly:

  • Liquid level alarm light
  • Horizontal receiver with liquid level indicator
  • One low pressure switch per suction group
  • Dual pressure relief valve assembly
  • Solid state optical low level alarm Controls:
  • Replaceable core filter drier and sight glass
  • Einstein Microprocessor w/phone modem & software
  • Temperature Sensors shipped loose for field installation

Suction Assembly;

  • One room sensor per evaporator
  • Brass shell replaceable core suction filter per compressor
  • One termination sensor per evaporator (positive defrost)
  • Suction accumulator (insulated) per compressor
  • Adjustable head pressure control valves.
  • Split condenser valve(s) mounted on rack
  • Hot gas bypass per suction group

RACK OPTIONS

Micro Processor Controls: Controls:

  • Controls up to 15 compressors/unloaders in three suction groups.
  • Low pressure switch per compressor.
  • Controls up to 12 pairs of fans for head pressure control.
  • Mechanical defrost timer.(gang timer)
  • Options include: Oil pressure transducers, Power monitor,
  • Mechanical alarm.
    remote communications, Room Temp. control.
  • EPR valves and Suction stop EPR valves.
  • Alarm functions: Refrigerant level, low/high suction and discharge
  • Liquid line solenoid valves mounted on rack
    pressures, oil failure, refrigerant leak detection.
  • Adjustable head pressure control valves.
  • Split condenser valve kit.
    Compressors:
  • Scroll, Open drive, other manufacturers of compressors.
  • Eight compressors maximum.
    Defrost circuits: (Please specify quantity, net capacity and defrost type for each circuit and suction group)
  • Electric: Includes both liquid and suction isolation ball valves, liquid and suction solenoids as well as fan and heater contactors
  • Hot Gas: Includes liquid, suction and hot gas isolation ball valves, and liquid, suction and hot gas solenoids as well as fan contactors
  • Priority One reverse cycle individual circuit hot gas defrost.
    The Priority One hot gas defrost design consists of using the suction line as a dedicated hot gas supply line and the liquid line as a dedicated condesate or hot gas return line during the defrost cycle. Hot gas enters the evaporator through the drain pan loop, then through suction header and flows in a reverse cycle through the evaporator, exiting through a side port on the distributor and through the TXV & LLSV bypass line before entering the liquid line. Termination is accomplished by a field installed temperature sensor located on the TXV & LLSV bypass line at the evaporator.
  • Four Pipe Soft Gas defrost
    The four pipe soft gas defrost design consists of supplying hot gas through dedicated common hot gas supply line and returning condensate and/or hot gas through a common hot gas return line. Upon initiation of defrost, the hot gas supply line is slowly pressurizied for approximately 30 seconds by a smaller secondary hot gas valve prior to the main hot gas valve opening. Hot gas enters the evaporator through the suction header and flows in a reverse cycle through the evaporator, exiting through a side port on the distributor. Condensate and/or hot gas leaving the evaporator is returned to a dedicated hot gas return line. Both the hot gas supply and return lines are drained through drain lines when not in use for defrost. Termination is accomplished by a field installed temperature located on the hot gas return line at the evaporator.
  • Off Cycle: Includes both liquid and suction isolation ball valves. (Liquid and suction solenoids optional).
  • Circuit Stubs: Includes both liquid and suction isolation ball valves (only up to 3-1/8″)